Block-Combined Honeycomb
description1
|
Item |
Unit |
MLM-160 |
MLM-180 |
MLM-200 |
|
Porosity |
% |
60 |
56 |
54 |
|
Maximum operating temperature |
ºC |
1180 |
1180 |
1180 |
|
Heat capacity |
kJ/kg.k |
0.79 |
0.88 |
0.92 |
|
Crushing strength |
kN/cm2 |
35 |
38 |
40 |
|
Water absorption |
% |
<0.5 |
<0.5 |
<0.5 |
|
Specific surface area |
m2/m3 |
524 |
590 |
660 |
|
Test weight |
kg/m3 |
900 |
998 |
1060 |
|
Bulk density |
g/cm3 |
2.25-2.35 |
2.25-2.35 |
2.25-2.35 |
Block-Combined Honeycomb Structural Characteristics
1、Modular Assembly:Standard honeycomb cells (such as hexagonal or rectangular) are spliced or nested to form a block structure. The cells are secured by mechanical interlocking, bonding, or welding, enabling rapid assembly and disassembly.
2、Honeycomb structures exhibit orthotropic properties, meaning that mechanical properties vary significantly along the L (length), W (width), and T (thickness) directions:
L direction: Highest compressive strength, suitable for load-bearing structures.
W direction: Weak shear strength, requiring reinforcement with thicker walls or filler materials.
T direction: Low compression modulus perpendicular to the honeycomb plane, but overall rigidity can be improved through a sandwich structure (such as a honeycomb core + faceplate).
Sub-honeycomb Optimization:Some designs utilize a "nested sub-honeycomb" structure, with a thick-walled sub-honeycomb at the center and a thin-walled matrix honeycomb at the periphery. This density gradient achieves a balance between energy absorption and load-bearing capacity.